近年来,城镇CNG储配站发展很快,其燃气出口温度控制模式一般采用手动启停热水锅炉控制,
本人根据杭燃滨江CNG储配站一年多来的运行分析,发现采用这种控制模式不仅温度波动幅度
大,而且经济性较差。针对这种情况,在SIEMENS S7-300控制系统中建立燃气出口温度PLC自控
模块,并对原热水循环系统进行少量改造,即可取得较好的控制效果。