Abstract

LPG(液化石油气)爆炸极限约为2%~10%,一旦从储存系统泄漏到大气环境中,极易引

起火灾爆炸等事故。因此,LPG储存站、储配站和灌装站的储罐布置应考虑防火间距。本文采用超压-冲量准则、世界银行推荐危害关系式模拟计算不同容积LPG储罐发生泄漏爆炸伤害半径,并将计算结果对比分析,确定防火安全间距,其结果可作为LPG储存站、储配站和灌装站建设的参考依据。


Keywords

蒸气云爆炸 液化石油气 伤害半径 超压-冲量准则 TNT当量